Home/ Systems/ Flooring Systems/ Super S1 Radiant Floor System
System 04

Installation System on Radiant Floor

Super S1 C2TE-S1 system over Floor K300 or LicaPlan screed: deformable tile installation over underfloor heating

System Build-Up

Layer-by-layer system specification

Tiling over underfloor heating requires a deformable S1 tile adhesive, because a non-deformable adhesive cannot absorb the repeated thermal expansion and contraction caused by heating cycles, leading to tile detachment over time. This system pairs either Floor K300 or LicaPlan screed (both underfloor heating compatible) with Super S1 flexible tile adhesive, providing a complete thermally-compatible tiling build-up.

Allow the screed to complete at least two full thermal cycles at full operating temperature before tiling. This allows hygrometric shrinkage to complete and prevents cracking at the adhesive interface.

Super S1 Radiant Floor System Build-Up
System Layers

Products

1
Layer 1
Base / Existing Structure
Structural concrete or existing floor. Fix edge insulation strips (min. 5mm) along all walls and columns before laying the screed. Install vapour barrier if rising damp is present.
2
Layer 2: Screed with Heating Coils
Floor K300 or LicaPlan
Both products are underfloor heating compatible. Maintain minimum screed depth over heating coils. Allow at least two full thermal cycles at operating temperature before tiling.
Choose your screed
Floor K300 Self-levelling compound. 3 to 40mm, walkable in 4 hours, tilable in 24 hours. Best for thinner builds and fast programmes.
LicaPlan Traditional floor screed. 3 to 6cm, floating or bonded. Min. 3cm over UFH panel castellations. Best for thicker builds and standard programmes.
3
Layer 3: Flexible Tile Adhesive
Super S1
C2TE-S1 deformable flexible tile adhesive. The S1 classification absorbs thermal movement from heating cycles. Apply at 2 to 5mm with a 6 to 10mm notched trowel. Back-butter tiles over 900cm².
View product
4
Layer 4: Tile
Ceramic or Stone
All tile types: ceramic, porcelain and stone. Stone and marble particularly benefit from thermal mass when installed over underfloor heating. Allow foot traffic after 24 to 36 hours.
5
Layer 5: Grout
FugaTop Grout
Select FugaTop 0_8 or FugaTop 3_20 based on tile format and joint width specification.
Products in This System

Everything you need for this system

Floor K300

Floor K300

Self-levelling compound 3 to 40mm. UFH compatible. Walkable in 4 hours, tilable in 24 hours. UNI EN 13813 CT-C30-F5.

View product
LicaPlan

LicaPlan

Traditional floor screed 3 to 6cm. UFH compatible, min. 3cm over panel castellations. Floating or bonded. UNI EN 13813 CT-C25-F4.

View product
Super S1

Super S1

Deformable C2TE-S1 flexible tile adhesive. S1 classification absorbs thermal movement from heating cycles. UNI EN 12004 and UNI EN 12002.

View product
FugaTop Grout

FugaTop Grout

Available as FugaTop 0_8 (0 to 8mm joints) and FugaTop 3_20 (3 to 20mm joints).

Specify this flooring system

Contact our technical team for product quantities, NBS specification support and project-specific advice.