High Rise EWI

External Wall Insulation systems for buildings over 11 metres: non-combustible mineral wool systems, wind load design, pull-out testing and full technical support from specification to completion.

Mineral Wool EWI Wind Load Calculations Pull-Out Testing Non-Combustible Systems Available Building Safety Act Compliant
Why High Rise Requires a Different Approach

Safe specification and installation on buildings over 11 metres

Following the Grenfell Tower fire and the subsequent Building Safety Act 2022, the specification of external wall insulation systems on buildings over 11 metres has come under significant scrutiny. Fire safety is paramount, and under no circumstances should combustible materials be used in the external wall of a high-rise residential building.

Licata's approach to high-rise specification is rigorous. We supply mineral wool EWI systems that are non-combustible, fully tested and supported by project-specific wind load calculations, pull-out testing and site-specific detailing, ensuring every system is correctly designed and safely installed.

Our technical team can support specification from initial system selection through to completion, providing U-value calculations, condensation risk analysis, CAD detail drawings and contractor support throughout the project.

Building Safety Act: Key Requirements

What changes above 11 metres

Above 11 metres: no combustible materials in the external wall
Regulation 7(2) of the Building Regulations prohibits combustible materials in the external wall of residential buildings over 11 metres. Insulation, sheathing and fixings must be non-combustible or of limited combustibility.
BS 8414 and BR 135: large-scale fire testing
The gold standard for EWI fire performance on high-rise buildings. Systems tested to BS 8414 are assessed under BR 135 criteria, confirming that fire will not spread via the external wall.
Wind loads: BS EN 1991-1-4
Project-specific wind load calculations must be completed. Fixing patterns must be designed to ensure pull-out and pull-through values exceed maximum wind loads for the building height, location and form.
PAS 2035: retrofit projects
Publicly funded retrofit EWI projects on high-rise buildings must comply with PAS 2035, requiring a Retrofit Assessor, Retrofit Coordinator and TrustMark-registered installation contractor.
Fire Performance

Non-combustible mineral wool systems for high-rise applications

Licata's mineral wool EWI systems use A1-classified stone wool insulation, the same inorganic rock wool material used in high-rise EWI installations across the UK. Mineral wool is non-combustible, will not spread flame and emits negligible smoke and fumes in the event of a fire.

The fire classification of a complete EWI system depends on the insulation type, sheathing board and finish coating combined. The table opposite shows indicative fire classifications for Licata system configurations. Please contact our technical team to confirm the fire classification applicable to your specific project.

Important Note
Fire classifications shown are indicative based on the insulation and finish type. Licata does not make system-level fire classification claims without project-specific confirmation. All high-rise specifications must be reviewed by our technical team before finalisation.
Indicative System Fire Classifications
System
Substrate
Finish
Indicative Class
LIC-EWI-001
Masonry + Mineral Wool
Silicone Render
A2-s1,d0
LIC-EWI-002
Masonry + Mineral Wool
Clay Brick Slips
A1
LIC-EWI-007
Steel Frame + Mineral Wool
Silicone Render
A2-s1,d0
LIC-EWI-008
Steel Frame + Mineral Wool
Clay Brick Slips
A1

Indicative classifications based on component materials. System-level fire classification must be confirmed with Licata's technical team for each specific project. Classifications do not substitute for BS 8414/BR 135 system testing where required.

Our Approach

Four steps to safe high-rise specification and installation

Every Licata high-rise EWI project follows a structured four-stage process, from initial system selection through pre-installation surveys and site-specific engineering, to installation support and aftercare. This process ensures every system is correctly specified, safely installed and properly maintained.

STEP 01

Initial Specification

System selection: non-combustible or limited combustibility, appropriate to building height and substrate
U-value calculations: project-specific, confirming target U-values are achieved
Condensation risk analysis: confirming no interstitial condensation risk
Preliminary specification and CAD detail drawings
Indicative budget costings and funding guidance where applicable
STEP 02

Pre-Installation

Structural survey: confirming building condition and substrate suitability for EWI
Ventilation checks: confirming adequate ventilation is in place
Pull-out testing to ETAG 014: minimum 15 tests, confirming fixing performance into the substrate
Wind load calculations to BS EN 1991-1-4: site-specific fixing patterns designed from results
Site-specific CAD detail drawings agreed with the installing architect or contractor
STEP 03

Installation Support

Licata-approved and suitably experienced installation contractors only
Site inspections: regular visits to inspect standard of work and applicator competence
Site reports issued after each inspection visit, including any required actions
Toolbox talks and on-site management training available
Dedicated Licata technical contact for the project duration
STEP 04

Aftercare & Warranties

Project-specific O&M manual issued on completion, covering the exact system installed
Maintenance, cleaning and inspection guidance included
Repair guidance for minor and full patch repairs
Resident information pack: guidance on living in a building following EWI installation
Third-party insurance-backed warranties available on eligible schemes
EWI Systems

Licata mineral wool systems suitable for high-rise applications

Licata's mineral wool EWI systems are supplied for use on masonry and steel frame high-rise buildings. All systems below use mineral wool insulation, which is non-combustible and classified A1 to EN 13501-1. For high-rise applications, the Masonry Mineral Wool and Steel Frame Mineral Wool build-ups with clay brick slips are A1 classified build-ups, tested and certified by KIWA. Silicone render finishes achieve A2-s1,d0. Please speak to our technical team to confirm system suitability for your specific project.

Masonry Mineral Wool Silicone Render
LIC-EWI-001 · Masonry
Masonry, Mineral Wool, Silicone Render

Mineral wool insulation adhesively and mechanically fixed to masonry, with reinforced basecoat and silicone render finish. Standard system for masonry high-rise retrofit.

View system
Masonry Mineral Wool Clay Brick Slips
LIC-EWI-002 · Masonry
Masonry, Mineral Wool, Clay Brick Slips

Mineral wool system with fired clay brick slip finish. Delivers traditional brick appearance on tower blocks and high-rise residential with a fully mineral build-up.

View system
Steel Frame Mineral Wool Silicone Render
LIC-EWI-007 · Steel Frame
Steel Frame, Mineral Wool, Silicone Render

A1 fibre cement board sheathing on steel frame, mineral wool insulation, silicone render finish. Suitable for high-rise steel frame new build and modular construction.

View system
Steel Frame Mineral Wool Clay Brick Slips
LIC-EWI-008 · Steel Frame
Steel Frame, Mineral Wool, Clay Brick Slips

Clay brick slip finish on steel frame with A1 sheathing board and mineral wool insulation. Achieves a traditional brick appearance on high-rise steel frame buildings.

View system
Why Licata for High Rise?

Technical rigour at every stage

Non-Combustible Insulation Throughout

All Licata mineral wool EWI systems use A1-classified stone wool insulation, non-combustible inorganic rock wool that will not spread flame, emits negligible smoke in fire, and is suitable for buildings of all heights under Regulation 7(2).

Wind Load Calculations to BS EN 1991-1-4

Every high-rise project receives a building-specific wind load calculation from our technical team. Fixing patterns are designed from the results, ensuring pull-out and pull-through values exceed the maximum design wind loads for each zone of the building.

Pull-Out Testing to ETAG 014

A minimum of 15 pull-out tests are completed on site by the fixing manufacturer prior to installation, providing project-specific data on the loads fixings will resist into the actual substrate. Further tests are completed as works commence to confirm consistency.

Site-Specific Detailing and CAD Drawings

Licata's technical team produces project-specific CAD detail drawings for every high-rise project, covering window reveals, eaves, sills, movement joints and any other critical junctions, agreed with the installing architect or contractor before works begin.

Experienced Installation Contractors

Licata works only with approved and suitably experienced EWI installation contractors for high-rise schemes. Site inspections are carried out regularly throughout the project, with written reports issued after each visit.

Full Aftercare and O&M Documentation

Every completed high-rise project receives a project-specific O&M manual covering the exact system installed, maintenance requirements, repair guidance and resident information. Third-party insurance-backed warranties are available on eligible schemes.

Standards & Compliance

Licata's mineral wool EWI systems are designed for compliance with Building Regulations Regulation 7(2), PAS 2035 and BS EN 1991-1-4. Speak to our technical team to confirm which system certifications apply to your project.

Regulation 7(2) Compliant
BS EN 1991-1-4 Wind Load
EN 13501-1 Fire Class
PAS 2035 Compatible
ETAG 014 Pull-Out Testing

Specify Licata for your high-rise project

Our technical team provides system specifications, wind load calculations, U-value calculations, CAD details and site support. Contact us to discuss your project requirements.