EWI Insulation

Mineral Wool EWI Slabs

Non-combustible stone wool insulation slabs for Licata external wall insulation systems, in dual density and high density grades. 1200 x 600 mm, thicknesses from 30 mm to 250 mm.

Euroclass A1 Insulation Dual Density High Density Vapour Open
Request a Quote EWI Systems
Mineral wool insulation slab for external wall insulation
Overview

Stone wool insulation for render and brick slip EWI systems

Made from volcanic rock spun into fibres, stone wool gives a rigid, dimensionally stable slab that does not burn, lets water vapour pass through and resists water penetration. Supplied in two grades: the dual density slab for standard render and brick slip systems on masonry and framed substrates, and the high density slab where a firmer board is specified. Both are fixed with Licata adhesive and mechanical fixings as part of a certified Licata EWI build-up.

Non-combustible

The slab achieves Euroclass A1, the highest reaction-to-fire class. The classification of the full wall build-up is confirmed by the relevant Licata system certificate.

Dense Outer Face

A firm, even surface for the reinforced base coat that also resists over-driven fixings.

Vapour Open

Vapour resistance close to still air, with water-repellent fibres that keep liquid water out. Suited to breathable systems on solid-wall refurbishment.

Continuous Insulation

Tightly butted slabs knit together into an unbroken insulating layer, cutting heat loss through gaps.

Acoustic Improvement

Test evidence shows up to 8 dB improvement in weighted sound reduction, depending on the substrate.

Easy to Install

Standard 1200 x 600 mm format, cut with a hand saw, laid in brick bond. Thicknesses over 250 mm are built up in two layers.

Specification

Two grades to suit the system

Dual Density (DD) Slab

The standard EWI slab. A denser outer layer gives a solid face for the base coat, while the softer underside takes up unevenness in the substrate. The outer face is marked THIS SIDE UP.

Reaction to fireEuroclass A1
Thermal conductivity0.036 W/mK
Tensile strength≥ 10 kPa
Compressive strength≥ 10 kPa
Size1200 x 600 mm
Thickness50 to 250 mm (10 mm steps)

High Density (HD) Slab

For external wall insulation systems where a higher density board is required.

Reaction to fireEuroclass A1
Thermal conductivity0.038 W/mK (30 to 40 mm)
0.039 W/mK (over 40 mm)
Tensile strength≥ 15 kPa
Compressive strength≥ 10 kPa
Size1200 x 600 mm
Thickness30 to 200 mm (10 mm steps)
Thermal Performance

Dual density slab thickness by target U-value

Indicative thicknesses for two typical substrates. Ask the Licata technical team for a project-specific U-value calculation.

U-value (W/m²K)New build steel frame
DD slab (mm)
Refurbishment 215 mm block
DD slab (mm)
0.3050110
0.2860120
0.2670130
0.2480140
0.2290150
0.20100170
0.18120190
0.16140210

Steel frame: 12 mm cement particle board, 100 mm steel frame fully filled with mineral wool, 2 x 12.5 mm plasterboard. Block: 215 mm dense concrete block, 13 mm plaster. Full table in the technical data sheet.

Specify mineral wool EWI slabs

Technical data sheet, U-value calculations, fixing calculations and system certificates from the Licata technical team.